Clinical or Case Report

Implantology. 30 June 2019. 86-94
https://doi.org/10.32542/implantology.2019007

ABSTRACT


MAIN

  • Ⅰ. Introduction

  • Ⅱ. Case Report

  • Ⅲ. Discussion

  • Ⅳ. Conclusion

Ⅰ. Introduction

Computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been widely used in implant prosthodontics1. A systematic review concluded that survival rates of CAD/CAM fabricated implant-supported crowns were comparable to those of conventionally fabricated implant-supported crowns and implant survival was unaffected by the fabrication technique2.

The CAD/CAM fabrication requires accurate virtual models3,4,5. Virtual models are either directly captured intraorally with intraoral scanners or extraorally through scanning of stone casts with laboratory scanners3,4,5. Intraoral scanning systems have numerous benefits for clinicians, such as accurate digitization with real-time visualization, easy and selective rescan process on wrong scanned areas, data fusion, and enhanced patient comfort3,5,6,7,8,9. However, between five and ten percent of clinicians use intraoral scanners7. In other words, most clinicians still use conventional impression materials due to their high detail accuracy and relative cost-efficiency7,9,10. However, additional time and effort are required for vacuum mixing, impression pouring, and waiting for the stone to set11.

Continuous technological improvement in digital dentistry generates new workflows5. Impression scanning technology has been recently developed and it shows a good accuracy, repeatability, and reproducibility12,13,14,15,16,17. Matta et al.15 anticipated that the impression scanning method can be a clinical alternative when intraoral scanners cannot be used. However, up to date, no clinical report for fabricating an implant-supported crown with the impression scanning method is available. In addition, a dental CAD program for fabricating an implant-supported crown with the impression scanning method has not been developed yet. The purpose of this case report is to introduce a novel approach for fabricating an implant-supported crown with impression scanning and CAD/CAM technologies.

Ⅱ. Case Report

A healthy 59-year-old man presented for the replacement of a missing mandibular left second molar. A bone level implant (s-Clean Tapered II Implants; Dentis, Daegu, Korea) was placed and a short scan body (H-Scan Body; Dio Implant Inc, Busan, Korea) was secured. After osseointegration and the soft tissue healing (Fig. 1), a closed-mouth tray (Chiyou Bite Tray; Asia Dental, Daegu, Korea) was evaluated intraorally and the patient was instructed to close into maximal intercuspation18,19,20. A closed-mouth impression was made with polyvinyl siloxane materials (Aquasil Ultra LV, Aquasil Ultra XLV; Dentsply Sirona, Milford, USA) (Fig. 2).

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F1.jpg
Fig. 1.

Placed scanbody at the mandibular left second molar site.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F2.jpg
Fig. 2.

Closed-mouth impression of the mandibular left dentition and scanbody.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

In a laboratory, the tray handle was fixed on a scan plate by using putty silicone (blue eco; DETAX GmbH, Ettlingen, Germany). The impression was placed into a laboratory scanner (D700; 3Shape, Copenhagen, Denmark). The first order was made with CAD software (3Shape Dental System; 3Shape). An icon of the mandibular left second molar was selected on the screen. A crown module was applied. Therefore, the CAD software regards the scan body as an abutment tooth that required a crown restoration. The scan setting was “Impression” and “Posterior triple tray”. Impression scanning was performed with the laboratory scanner (Fig. 3). The maxillary and mandibular impressions were aligned with a best-fit algorithm (Figs. 4 and 5)4. The next process step for the design of a crown was not proceeded and the scan data were saved.

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F3.jpg
Fig. 3.

Software view of the closed-mouth impression.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F4.jpg
Fig. 4.

Software view of the maxillary and mandibular impressions, lingual view. Note the red and blue points which are the same area on the close-mouth impressions.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F5.jpg
Fig. 5.

Software view of the closed-mouth impression after alignment. A, Lingual view. B, Buccal view.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

The second order was created for the virtual design of an implant-supported crown. An icon of the mandibular left second molar was chosen. An implant restoration module was applied. “Abutment”, “Anatomy”, and “Zirkon” were clicked. The object type of scan settings was “Digital impression”. Therefore, the CAD software regarded that the scan data was obtained from an intraoral scanner system. Information of the implant and scan body was registered in the second order. The impression scan data were opened (Fig. 6). Library data of the scanbody was superimposed on its captured image from the impression with a 3-point matching technique (Fig. 7)4,21. A customized abutment and a crown restoration were designed (Fig. 8)22,23. The arches were arbitrarily mounted in a virtual articulator and the eccentric occlusion was evaluated (Fig. 9)3,24. The finished design was transferred to a 5-axis milling machine (Arum 5X-200; DoowonID Co, Daejeon, Korea). A customized titanium abutment and a zirconia crown were milled (Fig. 10). The milled crown was sintered in a furnace (Austromat µSiC; Dekema Dental-Keramiköfen GmbH, Freilassing, Germany).

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F6.jpg
Fig. 6.

Software view of scan data. A, Maxillary left dentition. B, Mandibular left dentition and scanbody.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F7.jpg
Fig. 7.

Software view of the superimposed image of the scan body with 3-point matching technique.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F8.jpg
Fig. 8.

Software view of the CAD design of an implant-supported crown.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F9.jpg
Fig. 9.

Software view of the virtual mounting.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F10.jpg
Fig. 10.

Milled abutment and zirconia crown.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

The customized abutment was secured with a torque of 35Ncm (Fig. 11). The screw access channel was filled with polytetrafluoroethylene tape (ePTFE NASA SEAL; Han Yang Chemical Co, Incheon, Korea) and composite resin (UniFil LoFlo Plus; GC Corp, Tokyo, Japan)25. The definitive crown was luted with definitive cement (RelyX Ultimate Adhesive Resin Cement; 3M ESPE, St Paul, USA) (Fig. 12).

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F11.jpg
Fig. 11.

CAD/CAM abutment in place.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

http://static.apub.kr/journalsite/sites/kaomi/2019-023-02/N0880230202/images/kaomi_23_02_02_F12.jpg
Fig. 12.

Definitive restoration in place, 2 weeks after placement.
Ju-Hyoung Lee : Fabricating an Implant-Supported Crown with Impression Scanning Technology. Implantology 2019

Ⅲ. Discussion

Fabrication of the implant-supported crown by using the impression scanning method was described. By using this technique, the intraoral situation is accurately transferred without an intraoral scanner and a stone cast. Therefore, the implant-supported crown is rapidly fabricated with the streamlined process.

Although the impression scanning method has shown a good accuracy and repeatability, scanning deep concave surfaces of the impression may be technically challenging12,13,14,15,16,17. Therefore, the selective removal of the vestibule area in the impression is recommended. Another disadvantage is that creating the 2 separate orders is required as a module for fabricating an implant-supported crown with impression scanning is not developed. Impression scanning is available only when fixed dental prostheses for natural teeth are indicated. As the scan body is regarded as the tooth in the first order of the CAD program, the impression scanning is available. As the impression scan data is regarded as intraoral scan data in the second order, the scan body information can be registered. Therefore, further improvements of the CAD program are necessary so that the data acquisition and design process can be performed in a single order. In addition, the precision of impression scanning with regard to the scan body dimension, the scan body angulation, and the scan body distance should be investigated4,15.

Ⅳ. Conclusion

For the CAD/CAM fabrication of the implant-supported crown, impression scanning can be a clinical alternative to intraoral scanning and cast scanning. The presented technique also simplifies the clinical and laboratory procedure. However, continuous software development is necessary for user convenience.

References

1
Kapos T, Ashy LM, Gallucci GO, et al. Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry. Int J Oral Maxillofac Implants. 2009; 24(suppl): 110-117.
2
Kapos T, Evans C. CAD/CAM technology for implant abutments, crowns, and superstructures. Int J Oral Maxillofac Implants. 2014; 29(suppl): 117-136.
10.11607/jomi.2014suppl.g2.324660194
3
Alghazzawi TF. Advancements in CAD/CAM technology: Options for practical implementation. J Prosthodont Res. 2016; 60: 72-84.
10.1016/j.jpor.2016.01.00326935333
4
Fluegge T, Att W, Metzger M, et al. A novel method to evaluate precision of optical implant impressions with commercial scan bodies-an experimental approach. J Prosthodont. 2017; 26: 34-41.
10.1111/jopr.1236226466158
5
Joda T, Ferrari M, Gallucci GO, et al. Digital technology in fixed implant prosthodontics. Periodontol 2000. 2017; 73: 178-192.
10.1111/prd.1216428000274
6
Schepke U, Meijer HJ, Kerdijk W, et al. Digital versus analog complete-arch impressions for singleunit premolar implant crowns: operating time and patient preference. J Prosthet Dent. 2015; 114: 403-406.
10.1016/j.prosdent.2015.04.00326047800
7
Zimmermann M, Mehl A, Mörmann WH, et al. Intraoral scanning systems - a current overview. Int J Comput Dent. 2015; 18: 101-129.
8
Chochlidakis KM, Papaspyridakos P, Geminiani A, et al. Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis J Prosthet Dent. 2016; 116: 184-190.
10.1016/j.prosdent.2015.12.01726946916
9
Henry PJ, Harnist DJ. Dimensional stability and accuracy of rubber impression materials. Aust Dent J. 1974; 19: 162-166.
10.1111/j.1834-7819.1974.tb05033.x
10
Lacy AM, Fukui H, Bellman T, et al. Time-dependent accuracy of elastomer impression materials. Part II: Polyether, polysulfides, and polyvinylsiloxane. J Prosthet Dent. 1981; 45: 329-333.
10.1016/0022-3913(81)90400-5
11
Joda T, Brägger U. Digital vs. conventional implant prosthetic workflows: A cost/time analysis. Clin Oral Implants Res. 2015; 26: 1430-1435.
10.1111/clr.1247625179680
12
Jeon JH, Choi BY, Kim CM, et al. Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners. J Prosthet Dent. 2015; 114: 549-553.
10.1016/j.prosdent.2015.04.01926182854
13
Jeon JH, Jung ID, Kim JH, et al. Three-dimensional evaluation of the repeatability of scans of stone models and impressions using a blue LED scanner. Dent Mater J. 2015; 34: 686-691.
10.4012/dmj.2014-34726438993
14
Jeon JH, Kim DY, Lee JJ, et al. Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner. J Adv Prosthodont. 2016; 8: 214-218.
10.4047/jap.2016.8.3.21427350856PMC4919492
15
Matta RE, Adler W, Wichmann M, et al. Accuracy of impression scanning compared with stone casts of implant impressions. J Prosthet Dent. 2017; 117: 507-512.
10.1016/j.prosdent.2016.07.02627881327
16
Mandelli F, Ferrini F, Gastaldi G, et al. Improvement of a digital impression with conventional materials: overcoming intraoral scanner limitations. Int J Prosthodont. 2017; 30: 373-376.
10.11607/ijp.513828697209
17
Lee B, Oh KC, Haam D, et al. Evaluation of the fit of zirconia copings fabricated by direct and indirect digital impression procedures. J Prosthet Dent. 2018; 120: 225-231.
10.1016/j.prosdent.2017.08.00329428522
18
Wilson EG, Werrin SR. Double arch impressions for simplified restorative dentistry. J Prosthet Dent. 1983; 49: 198-202.
10.1016/0022-3913(83)90500-0
19
Donovan TE, Chee WW. A review of contemporary impression materials and techniques. Dent Clin North Am. 2004; 48: 445-470.
10.1016/j.cden.2003.12.01415172610
20
Johnson GH, Mancl LA, Schwedhelm ER, et al. Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays. J Prosthet Dent. 2010; 103: 13-22.
10.1016/S0022-3913(09)60208-0
21
Lee JH. A completely cast-free, digital workflow for fabricating an implant-supported prosthesis with a new coded healing abutment. Implantol. 2019; 23: 32-41.
10.32542/implantology.2019003
22
Parpaiola A, Norton MR, Cecchinato D, et al. Virtual abutment design: A concept for delivery of CAD/CAM customized abutments - report of a retrospective cohort. Int J Periodontics Restorative Dent. 2013; 33: 51-58.
10.11607/prd.127223342347
23
Goldstein G, Vafiadis D, Kim J. Finding Z: A mathematical method for predicting tissue position after implant abutment-restoration placement. J Prosthet Dent. 2014; 112: 322-324.
10.1016/j.prosdent.2013.10.02724793352
24
Mehl A. A new concept for the integration of dynamic occlusion in the digital construction process. Int J Comput Dent. 2012; 15: 109-123.
25
Moráguez OD, Belser UC. The use of polytetrafluoroethylene tape for the management of screw access channels in implant-supported prostheses. J Prosthet Dent. 2010; 103: 189-191.
10.1016/S0022-3913(10)60029-7
페이지 상단으로 이동하기